1.
Rev. bras. ciênc. vet ; 28(1): 57-60, jan./mar. 2021. tab
Article in Portuguese | LILACS, VETINDEX | ID: biblio-1491702

ABSTRACT

Objetivou-se verificar a compatibilidade entre diferentes marcas de tiras reagentes para urinálise, tanto de uso veterinário, como de uso humano, e confrontar os parâmetros semiquantitativos desse instrumento com métodos quantitativos. Para isso, foram analisadas 77 amostras frescas de urina de cães e gatos e testados 04 modelos de tiras reagentes. Quanto à densidade urinária, houve correlação razoável entre os métodos quantitativo e semiquantitativo naquelas amostras com pH ácido, mas não naquelas com pH neutro ou alcalino. Quanto à concentração proteica, houve similaridade de 53,3% a 83,3% entre as marcas testadas e quando comparadas com a análise fotométrica houve uma correlação razoável (rs = 0,69752 a 0,75074). Em ponto de corte de 15mg/dL de proteína, a sensibilidade da tira reagente foi 82,5% e 100% para urina canina e felina, respectivamente. No tocante à hematúria, houve divergência razoável entre a sedimentoscopia e as diferentes marcas de tiras reativas. Quanto à piúria, há uma baixa sensibilidade das tiras em relação às amostras caninas com muitos resultados falso-negativos (33% a 75%), enquanto em amostras felinas a sensibilidade foi de 100%. Assim, independente da marca, as tiras reagentes devem servir apenas como teste rápido de triagem, sendo mais apropriado o uso de métodos quantitativos na avaliação clínica do paciente a partir da urinálise.


The aim was to verify the compatibility between different brands of urinary dipsticks, for both human and veterinary use, and to compare the semiquantitative parameters of this instrument with quantitative methods. For this, 77 fresh samples of urine from dogs and cats were analyzed e and 04 models of reagent strips were tested. Regarding urinary density, a reasonable correlation was observed between the quantitative and semiquantitative methods in those samples with acidic pH, which did not occur in those with neutral or alkaline pH. Regarding the protein concentration, there was similarity from 53.3% to 83.3% between the brands and in the comparative analysis between the control strip and the photometric analysis, there was a reasonable correlation (rs = 0.69752 to 0.75074). In cut-off point of 15mg/dL protein, the sensitivity of the reagent strip was 82.5% and 100% for canine and feline urine, respectively. Regarding hematuria, there was a reasonable divergence of results between sedimentation and tested dipsticks. As for pyuria, there is a low sensitivity of the strips in relation to canine samples with many false negative results (33% to 75%), while in feline samples the sensitivity was 100%. Thus, regardless of the brands, the reagent strips should serve only as a rapid screening test, while the use of quantitative methods in the clinical evaluation of the patient from urinalysis is more appropriate.


Subject(s)
Animals , Cats , Dogs , Pets , Dogs/physiology , Chemical Phenomena , Cats/physiology , Indicators and Reagents , Urine/chemistry , Urinalysis/veterinary , Hematuria , Pyuria
2.
Rev. bras. ciênc. vet ; 28(1): 57-60, jan./mar. 2021. il.
Article in Portuguese | LILACS, VETINDEX | ID: biblio-1368822

ABSTRACT

Objetivou-se verificar a compatibilidade entre diferentes marcas de tiras reagentes para urinálise, tanto de uso veterinário, como de uso humano, e confrontar os parâmetros semiquantitativos desse instrumento com métodos quantitativos. Para isso, foram analisadas 77 amostras frescas de urina de cães e gatos e testados 04 modelos de tiras reagentes. Quanto à densidade urinária, houve correlação razoável entre os métodos quantitativo e semiquantitativo naquelas amostras com pH ácido, mas não naquelas com pH neutro ou alcalino. Quanto à concentração proteica, houve similaridade de 53,3% a 83,3% entre as marcas testadas e quando comparadas com a análise fotométrica houve uma correlação razoável (rs = 0,69752 a 0,75074). Em ponto de corte de 15mg/dL de proteína, a sensibilidade da tira reagente foi 82,5% e 100% para urina canina e felina, respectivamente. No tocante à hematúria, houve divergência razoável entre a sedimentoscopia e as diferentes marcas de tiras reativas. Quanto à piúria, há uma baixa sensibilidade das tiras em relação às amostras caninas com muitos resultados falso-negativos (33% a 75%), enquanto em amostras felinas a sensibilidade foi de 100%. Assim, independente da marca, as tiras reagentes devem servir apenas como teste rápido de triagem, sendo mais apropriado o uso de métodos quantitativos na avaliação clínica do paciente a partir da urinálise.


The aim was to verify the compatibility between different brands of urinary dipsticks, for both human and veterinary use, and to compare the semiquantitative parameters of this instrument with quantitative methods. For this, 77 fresh samples of urine from dogs and cats were analyzed e and 04 models of reagent strips were tested. Regarding urinary density, a reasonable correlation was observed between the quantitative and semiquantitative methods in those samples with acidic pH, which did not occur in those with neutral or alkaline pH. Regarding the protein concentration, there was similarity from 53.3% to 83.3% between the brands and in the comparative analysis between the control strip and the photometric analysis, there was a reasonable correlation (rs = 0.69752 to 0.75074). In cut-off point of 15mg/dL protein, the sensitivity of the reagent strip was 82.5% and 100% for canine and feline urine, respectively. Regarding hematuria, there was a reasonable divergence of results between sedimentation and tested dipsticks. As for pyuria, there is a low sensitivity of the strips in relation to canine samples with many false negative results (33% to 75%), while in feline samples the sensitivity was 100%. Thus, regardless of the brands, the reagent strips should serve only as a rapid screening test, while the use of quantitative methods in the clinical evaluation of the patient from urinalysis is more appropriate.


Subject(s)
Animals , Cats , Dogs , Reagent Strips/analysis , Cats/urine , Urinalysis/methods , Dogs/urine , Efficiency , Indicators and Reagents/analysis , Proteinuria/veterinary , Pyuria/veterinary , Urine Specimen Collection/methods , Hematuria/veterinary
3.
Ciênc. rural (Online) ; 51(3): e20200335, 2021. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1153852

ABSTRACT

ABSTRACT: The objective of the present study was to assess the treatment of dogs with ehrlichiosis (tropical canine pancytopenia (TCP)) with doxycycline hydrochloride associated or not with prednisolone on the hematological profile and serum proteins. Ten dogs with TCP were selected in the Small Animal Medical Clinic Veterinary Hospital, Federal University of Campina Grande-UFCG-PB, Brazil. The diagnosis was obtained by clinical examination, hemogram and immunochromatographic test (with anti Ehrlichia canis antibodies). Samples were distributed randomly in two experimental groups of five animals each (n = 5), named GD and GDP. The GD group was treated with doxycycline (5 mg/kg, VO, BID for 28 days) and the GDP group was treated with doxycycline at the same dose and duration and prednisolone (2 mg/kg, VO, BID, for five days). Four blood collections were made during the treatment period: a base collection (M0), one at 10 days (M10), a second at 21 days (M21) and another at the end of the treatment (M28). These samples were used for the tests erythrogram, leucogram, plateletgram and proteinogram (dose of total proteins, pre-albumin, albumin, albumin, α-1 globulin, α-2 globulin, ß-globulin, ɣ-globulin and C- reactive protein) in the Clinical Pathology Laboratory, Veterinary Hospital-UFCG-PB. Results, that presented normal distribution, was submitted to the Tukey test (P<0.05). Comparison of treatments GD and GDP showed that both promoted discreet and similar response in the hematological parameters at different times. Results obtained allowed the conclusion that both therapeutic protocols resulted in clinical, hematological parameter and proteinogram improvement, but the use of prednisolone at the dose administered during the first five days of treatment did not show more beneficial effects than isolated administration of doxycycline.


RESUMO: Objetivou-se com este estudo avaliar os efeitos do tratamento de cães com erliquiose monocítica canina (EMC) com cloridrato de doxiciclina associada ou não à prednisolona sobre o perfil hematológico e de proteínas séricas. Foram selecionados, na Clínica Médica de Pequenos Animais do Hospital Veterinário da Universidade Federal de Campina Grande (UFCG), 10 cães com EMC. O diagnóstico foi obtido através de exame clínico, hemograma e teste de imunoensaio imunocromatográfico (com anticorpos anti Ehrlichia canis). As amostras foram distribuídas aleatoriamente em dois grupos experimentais, com cinco animais cada (n=5), denominados GD e GDP. O grupo GD foi tratado com doxiciclina (5 mg/kg, VO, BID durante 28 dias) e o grupo GDP, tratado com doxiciclina na mesma dose e duração e prednisolona (2 mg/kg, VO, BID, durante 5 dias). Durante o período de tratamento, foram realizadas quatro coletas de sangue; uma coleta basal (M0), uma com 10 dias (M10), uma aos 21 dias (M21) e outra ao final do tratamento (M28). Dessas amostras foram realizados eritrograma, leucograma, plaquetograma e proteinograma (dosagem de proteínas totais, pré-albumina, albumina, α-1 globulina, α-2 globulina, ß-globulina, ɣ-globulina e proteína C-reativa) no Laboratório de Patologia Clínica do Hospital Veterinário da UFCG. Os resultados que apresentaram distribuição normal foram submetidos ao teste de Tukey (P<0,05). Ao comparar os tratamentos GD e GDP, observou-se que os dois promoveram resposta discreta e semelhante dos parâmetros hematológicos nos diferentes momentos. Os resultados obtidos permitem concluir que ambos os protocolos terapêuticos resultaram em melhora clínica e dos parâmetros hematológicos e do proteinograma. Porém, o uso da prednisolona na dose empregada durante os primeiros cinco dias de tratamento não demonstrou efeitos mais benéficos do que a administração isolada da doxiciclina.